Data di Pubblicazione:
2007
Abstract:
In this work we combine charge-pumping measurements with positive constant voltage stress to investigate trap generation in SiO2/ Al2O3 n-MOSFET. Trap density has been scanned either in energy or in position based on charge-pumping (CP) measurements performed under different operating conditions in terms of amplitude and frequency of the gate pulse. Our results have revealed that the traps are meanly localized shallow in energy level, deeper in spatial position and they are mostly generated near the Si/SiO2 interface. (C) 2007 Elsevier Ltd. All rights reserved.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Bulk traps; charge pumping (CP); energy distribution; high-k dielectrics; interface traps