An analysis of the non-volatile reaction products of aqueous Maillard model systems at pH 5, using reversed-phase HPLC with diode-array detection
Articolo
Data di Pubblicazione:
1996
Abstract:
An HPLC-diode array detection (HPLC-DAD) method was developed
for the direct analysis of reaction products of aqueous Maillard model systems.
The method was applied to mixtures of xylose or glucose refluxed with glycine or
lysine for up to 120 min with the pH maintained at 5 throughout heating. Four
types of chromatographic behaviour were apparent, ie unretained peaks, resolved
peaks and two broad bands. Glycine systems were dominated by unretained
peaks while systems based on lysine showed all four types of behaviour. By reference
to HPLC-DAD data for standard compounds, some of the resolved peaks
were tentatively attributed to pyrrole-like and furanone-like compounds.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Maillard; non-enzymic browning; HPLC; diode-array; glucose
Elenco autori:
Monti, SIMONA MARIA
Link alla scheda completa:
Pubblicato in: