Matrix-assisted laser desorption/ionisation time-of-flight characterisation of biodegradable aliphatic copolyesters
Articolo
Data di Pubblicazione:
2000
Abstract:
Matrix-assisted laser desorption/ionisation time-of-flight (MALDI-TOF) and the off-line size exclusion
chromatography matrix-assisted laser desorption/ionisation (SEC/MALDI) method has been applied to the
structural characterisation and the molar mass (MM) determination of a series of biodegradable
copolyesters synthesised by high temperature melt polycondensation reaction, and of two commercial
copolyesters with the trade name Bionolle. The MALDI-TOF spectra of these copolymers showed the
presence of cyclic oligomers in the lower mass region, in accord with expectations from polycondensation
kinetics, and the presence of all linear species expected from their method of synthesis. The presence of
unexpected linear species with olefin and carboxyl as end groups suggested the occurrence of undesirable
thermal degradation processes during the melt polycondensation reaction. The absolute average molar
masses obtained by the SEC-MALDI method turned out to be lower, by a factor of about two for succinate/
adipate copolymers, and by a factor of three for succinate/sebacate copolymers, with respect to those
computed by using polystyrene standards in SEC. Furthermore, the MALDI-TOF spectra of SEC fractions
allowed not only the detection of linear and cyclic oligomers contained in these samples, but also the
simultaneous determination of the average molar mass of both cyclic and linear oligomers. Due to the
smaller hydrodynamic volume of cyclic chains with respect to linear ones, the ratio (Mcycle/Mlinear)Ve at a
fixed elution volume was found to be 1.25, in good agreement with the theoretical value of 1.24
Tipologia CRIS:
01.01 Articolo in rivista
Elenco autori:
Carroccio, SABRINA CAROLA; Rizzarelli, Paola; Puglisi, Concetto
Link alla scheda completa: