Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Lung ultrasound B-lines and serum KL-6 correlate with the severity of idiopathic inflammatory myositis-associated interstitial lung disease

Articolo
Data di Pubblicazione:
2020
Abstract:
OBJECTIVE: Idiopathic inflammatory myositis-associated interstitial lung disease (IIM-ILD) significantly increases morbidity and mortality. Lung ultrasound B-lines and Krebs von den Lungen-6 (KL-6) are identified as new sonographic and serum markers of ILD, respectively. The aim of our work was to assess the role of B-lines and KL-6 as markers of the severity of IIM-ILD. For this purpose, the correlation among B-lines score, serum KL-6 levels, high-resolution CT (HRCT) score, and pulmonary function tests were investigated in IIM-ILD patients. METHODS: Thirty-eight patients with IIM-ILD underwent chest HRCT scans, lung ultrasound and pulmonary function tests (independently performed within 1 week) examination. To assess severity and extent of ILD at HRCT, the Warrick score was used. The B-lines score denoting the extension of ILD was calculated by summing the number of B-lines on a total of 50 scanning sites. Serum KL-6 levels (U/ml) was measured by chemiluminescent enzyme immunoassay. RESULTS: A significant correlation was found between the B-lines score and serum KL-6 levels (r = 0.43, P < 0.01), and between the Warrick score and serum KL-6 levels (r = 0.45, P < 0.01). A positive correlation between B-lines score and the Warrick score (r = 0.87, P < 0.0001) was also confirmed. Both B-lines score and KL-6 levels inversely correlated to diffusion capacity for carbon monoxide (r = -0.77, P < 0.0001 and r = -0.42, P < 0.05, respectively) and total lung capacity (r = -0.73, P < 0.0001 and r = -0.36, P < 0.05, respectively). Moreover, B-lines correlated inversely with forced vital capacity (r = -0.73, P < 0.0001), forced expiratory volume in 1 s (r = -0.69, P < 0.0001). CONCLUSION: B-lines score and serum KL-6 levels correlate with HRCT findings and pulmonary function tests, supporting their use as measures of IIM-ILD severity.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
B-lines; high-resolution CT; idiopathic inflammatory myositis-associated interstitial lung disease; KL-6; lung ultrasound; pulmonary function tests
Elenco autori:
Gargani, Luna
Autori di Ateneo:
GARGANI LUNA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/394273
Pubblicato in:
RHEUMATOLOGY (OXF. PRINT)
Journal
  • Dati Generali

Dati Generali

URL

http://www.scopus.com/record/display.url?eid=2-s2.0-85088678865&origin=inward
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)