Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

To the Editor - Higher incidence of esophageal lesions after atrial fibrillation ablation related to the use of esophageal temperature probes

Articolo
Data di Pubblicazione:
2015
Abstract:
BACKGROUND:Endoscopically detected esophageal lesions (EDELs) have been identified in apparently asymptomatic patients after catheter ablation of atrial fibrillation (AF). The use of esophageal probes to monitor luminal esophageal temperature (LET) during catheter ablation to protect esophageal damage is currently controversial. OBJECTIVE: The purpose of this study was to investigate the impact of the use of esophageal temperature probes during AF catheter ablation on the incidence of EDELs. METHODS: Eighty consecutive patients (mean age 63.8 ± 11.36 years; 68.8% men) with symptomatic, drug-refractory paroxysmal (n = 52, 65%) or persistent AF who underwent left atrial radiofrequency catheter ablation were prospectively enrolled. Posterior wall ablation was power limited (<=25 W). In the first 40 patients, LET was monitored continuously (group A), whereas no esophageal temperature probe was used in group B (n = 40 patients). Assessment of EDEL was performed by endoscopy within 2 days after radiofrequency catheter ablation. RESULTS: Overall, 13 patients (16%) developed EDELs after AF ablation. The incidence of EDELs was significantly higher in group A than group B (30% vs 2.5%, P < .01). Within group A, patients who developed EDEL had higher maximal LET during AF ablation than patients without EDEL (40.97 ± 0.92°C vs 40.14 ± 1.1°C, P = .02). Multivariable logistic regression analysis revealed the use of an esophageal temperature probe as the only independent predictor for the development of EDEL (odds ratio 16.7, P < .01). CONCLUSION: The use of esophageal temperature probes in the setting of AF catheter ablation per se appears to be a risk factor for the development of EDEL.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Atrial fibrillation; Atrioesophageal fistula; Catheter ablation; Esophageal lesion; Esophageal temperature monitoring
Elenco autori:
Fasano, Antonio
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/304536
Pubblicato in:
HEART RHYTHM
Journal
  • Dati Generali

Dati Generali

URL

http://www.scopus.com/inward/record.url?eid=2-s2.0-84939777867&partnerID=q2rCbXpz
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)