Comparison of CT and magnetic resonance mDIXON-Quant sequence in the diagnosis of mild hepatic steatosis
Articolo
Data di Pubblicazione:
2018
Abstract:
Objective: To determine the diagnostic performance of CT in the assessment of mild hepatic steatosis by comparison with MR mDIXON-Quant as
a reference standard, and to explore their clinical
applications.
Methods: In this prospective study 169 volunteers were
included. Each subject underwent CT and MR mDIXON-Quant examinations. Hepatic steatosis evaluations
were performed via liver attenuation alone (CT L), liver
to spleen attenuation ratio (CT L/S), difference between
liver and spleen attenuation (CT L-S), and MR mDIXON-Quant imaging. The effectiveness of CT L, CT L/S,
and CT L-S in diagnosing hepatic steatosis severity
of >=5%, >=10%, and >=15% was compared, using mDIXON-Quant results as standard.
Results: 65 subjects exhibited mild hepatic steatosis.
Hepatic steatosis measurement with mDIXON-Quant
was strongly correlated with the three CT methods.
Using cutoff value, the sensitivity and specificity of diagnosing hepatic steatosis >=5, >=10, and >=15% were 64.6,
91.3, 100%, and 90.4, 89.7, 93.0% for CT L; 50.8, 87.0,
100%, and 96.2, 98.6, 97.5% for CT L/S; and 67.7, 87.0,
100%, and 81.7, 98.6, 97.5% for CT L-S, respectively. ROC
analysis indicated that 58.9, 56.5, and 52.8 HU for CT L;
1.06, 0.98, and 0.90 HU for CT L/S; and 6.21,-1.04, and
-4.93 HU for CT L-S were cutoff values for diagnosing
hepatic steatosis >=5%,>=10%, and >=15%, respectively.
Conclusions: The three CT methods exhibit better agreements with mDIXON-Quant imaging for diagnosing
hepatic steatosis >=10%. Hence, CT and mDIXON-Quant
could serve as suitable tools for the accurate quantification of mild hepatic steatosis.
Significant finds of the study: The close agreement between the three different CT methods
(based on our cutoff values) and mDIXON-Quant
imaging suggests that CT could accurately diagnose
hepatic steatosis >=10%. Thus, CT and mDIXON-Quant
imaging can accurately measure mild hepatic
steatosis.
What this study adds: Only few studies have
compared hepatic steatosis quantification between
CT and mDIXON-Quant. We are the first to determine the diagnostic performance of unenhanced CT
for quantitatively assessing mild hepatic steatosis,
in reference to magnetic resonance mDIXON-Quant
imaging.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
fatty liver; female; hepatic portal vein
Elenco autori:
Veronese, Nicola
Link alla scheda completa:
Pubblicato in: