Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

A non-invasive optical method for mapping temperature polarization in direct contact membrane distillation

Articolo
Data di Pubblicazione:
2017
Abstract:
Membrane Distillation (MD) is a thermal membrane process allowing for a theoretical 100% rejection of non-volatile compounds (i.e. ions, macromolecules, colloids, cells), whereas vapour molecules permeate through a micro-porous hydrophobic membrane due to a difference of vapour pressure established across the membrane-self. The effective driving force and, then, the vapour trans-membrane flux is affected by temperature polarization phenomena occurring in the boundary layers adjacent to the membrane. The temperature values at the membrane surface are usually difficult to measure and only recently some invasive techniques were adopted for this scope. The aim of this work was to introduce luminescent molecular probing as an innovative technology for non-invasive and in-situ monitoring of thermal polarization in MD. Tris(phenantroline)ruthenium(II) chloride (Ru(phen)3) was selected as temperature sensitive luminescent probe and immobilized in a flat poly(vinylidene fluoride) electrospun nanofibrous membrane (PVDF ENM). Experiments showed the key role of the Ru(phen)3 and Lithium Chloride (LiCl) in the preparation of homogeneous PVDF ENM due to their ionic nature that improved the electrical conductivity of the polymeric solution favouring the electrospinning. Furthermore, PVDF ENM showed a good performance in Direct Contact Membrane Distillation (DCMD) process. The immobilization of the molecular probe allowed to optically monitoring the membrane surface temperature during DCMD experiments. On the other hand, the employment of an IR-camera permitted the evaluation of the temperature of the bulk of liquid streams. Therefore, the combination of these two optical techniques enabled to evaluate, in a direct and non-invasive way, the thermal polarization along the membrane module during DCMD experiments.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Membrane Distillation; MD; thermal membrane process; Direct Contact Membrane
Elenco autori:
Drioli, Enrico; Santoro, Sergio; Criscuoli, Alessandra; Figoli, Alberto; Desiderio, Giovanni; Lombardo, Giuseppe
Autori di Ateneo:
CRISCUOLI ALESSANDRA
DESIDERIO GIOVANNI
FIGOLI ALBERTO
LOMBARDO GIUSEPPE
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/330224
Pubblicato in:
JOURNAL OF MEMBRANE SCIENCE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)