Insights into the failure of the potential, neutral myocardial imaging agent TcN-NOET: physicochemical identification of by-products and degradation species

Articolo
Data di Pubblicazione:
2012
Abstract:
Introduction: The neutral complex [Tc-99m(N)(NOEt)(2)], often referred to as TcN-NOET [NOEt=N-ethoxy,N-ethyldithiocarbamate(1-)], was proposed several years ago as a myocardial imaging agent. Despite some favorable clinical properties evidenced during phase I and phase II studies, the overall results of the European and American phase III clinical studies have been judged insufficient for a successful approval process by the regulatory agencies. Methods: Non-carrier-added and carrier-added experiments using short-lived Tc-99m and long-lived Tc-99g have been utilized to prepare a series of bis-substituted [Tc(N)(DTC)(2)] complexes [DTC=dithiocarbamate(1-)]. They have been purified by means of chromatographic techniques (high-performance liquid chromatography and thin-layer chromatography) and identified via double detection (UV-vis and radiometry) by comparison with authenticated samples of Tc-99g compounds prepared by conventional coordination chemistry procedures. Results: The molecular structure of the lipophilic, neutral complex cis-[Tc(N)(NOEt)(2)] has been assigned by comparison with similar nitrido-Tc(V) complexes already reported in the literature. Novel bis-substituted nitrido-Tc complexes containing hydrolyzed portions of coordinated NOEt, namely, N-ethyldithiocarbamate [NHEt(1-)] and N-hydroxy, N-ethyldithiocarbamate [NOHEt(1-)], have been prepared and characterized by means of multinuclear nuclear magnetic resonance spectroscopy and mass spectrometry. Conclusions: Despite the identification of these "hydrolyzed" species, it is still unclear whether the failure to reach the clinical goal of the perfusion tracer [Tc-99m(N)(NOEt)(2)] is related to the degradation processes evidenced in this study or is the result of the mediocre imaging properties of the tracer.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Technetium radiopharmaceuticals; Coordination chemistry; Mass spectrometry; Myocardial imaging
Elenco autori:
Carta, Davide; Seraglia, Roberta; Bolzati, Cristina; Porchia, Marina; Refosco, Fiorenzo; Tisato, Francesco
Autori di Ateneo:
BOLZATI CRISTINA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/454500
Pubblicato in:
NUCLEAR MEDICINE AND BIOLOGY
Journal
  • Dati Generali

Dati Generali

URL

http://www.sciencedirect.com/science/article/pii/S0969805111002289
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)