Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

One axis gravity gradiometer for the measurement of Newton?s gravitational constant, G

Articolo
Data di Pubblicazione:
2003
Abstract:
This paper presents preliminary works concerning a new technique to measure the gravitational constant G, using a single axis gravity gradiometer designed to detect an off-line component of the gravity gradient tensor and able to reject the linear acceleration due to the vibrational noise (common mode rejection: CMR). The main part of such an instrument is a torsional mechanical oscillator which is forced at the frequency , by means of a gravitational torque produced with a system of two masses rotating at a frequency . The low frequency of the mechanical oscillator, together with a high sensitivity capacitive bridge measurement system, enables the detection of the gravitational signal with high accuracy, also in presence of quite high seismic noise. A precision of one part in in the determination of the gravitational torque was achieved in our laboratory with an integration time of about 5 h and a factor 10 can be easily gained performing the measurement in a place with a lower differential seismic noise. The detection accuracy can be translated into experimental accuracy in the determination of G if the physical parameters of the whole system are measured with the same relative error. The experiment proposed in this paper has strong similarities with the classic torsion balance [1], but it has some peculiarities that make it particularly interesting as follows: the oscillating system is in indifferent equilibrium under the action of the Earth gravity field, so that it can have any orientation with respect to the local vertical; the instrument can also be used in the absence of gravity (free fall experiment); the capacitive bridge pick-up system has a high transducer factor for converting mechanical signals into electrical signals which are much greater than the pre-amplifier noise, even for very small displacements of the oscillator.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Gravitazione; Gradiometro
Elenco autori:
Iafolla, Valerio; Nozzoli, Sergio
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/169054
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)