Data di Pubblicazione:
2014
Abstract:
Accurate evaluation of the Antenna Phase Center (APC) position is a key issue in radar applications. In this work we propose an approach for the APC position measurement in anechoic chamber. The presented method allows overcoming some limitations of the classical algorithm known as Two Point Approach, and it has been tested on two X-band antennas: a standard horn antenna and the three-horn array antenna mounted onboard the TELAER airborne Synthetic Aperture Radar system.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
airborne SAR antennas; Antenna Phase Center; SAR antennas
Elenco autori:
Perna, Stefano; Esposito, Carmen; Pauciullo, Antonio
Link alla scheda completa: