Studies on high voltage dc cable connection to supply the acceleration grids of the Neutral Beam Injector for DTT

Articolo
Data di Pubblicazione:
2022
Abstract:
The Divertor Tokamak Test facility (DTT) is the new tokamak under construction in Frascati (Italy), with the main aim of testing different divertor magnetic configurations and technologies in view of DEMO. The Heating and Current Drive function will be provided also by one Neutral Beam Injector (NBI), accelerating negative Deuterium ions with an energy of 510 keV, giving an output power of 10 MW maximum. The Acceleration Grid Power Supply (AGPS), with 3 stages rated 167 kV each, will feed the NBI accelerator. For optical reasons, the insulating gap among the acceleration grids is at the limit of the voltage holding in vacuum, therefore frequent arc breakdowns (BD) among the grids will occur, requiring the quick switch-off of the AGPS to limit the arc energy. For the AGPS, beside the ITER-like scheme including gas-insulated HV components, an innovative approach based on the Modular Multilevel Converter (MMC) technology is being considered. This would include air-insulated HV converters, requiring a huge building volume, which at present is not available in close proximity to the tokamak building. The alternative of installing the MMC converters in a new building to be erected in an available area located far from the tokamak, and connecting the AGPS to the load with HV coaxial cables, is under study. This paper presents the studies carried out to verify the impact of the cables length on the arc energy, in case of breakdown among the grids, and to estimate the magnitude of the voltage oscillations due to resonance effects. These oscillations can occur not only between each hot pole and the return conductor, endangering the cable insulation, but also between the return conductor and local ground, with potential consequences on the laying method, the human safety and the electromagnetic compatibility with sensitive apparatus nearby, which have all been evaluated.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Neutral Beam Injector; Acceleration Grid Power Supply; Modular Multilevel Converter; DTT
Elenco autori:
Murari, Andrea; Granucci, Gustavo
Autori di Ateneo:
GRANUCCI GUSTAVO
MURARI ANDREA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/414637
Pubblicato in:
FUSION ENGINEERING AND DESIGN
Journal
  • Dati Generali

Dati Generali

URL

https://www.sciencedirect.com/science/article/abs/pii/S0920379622003477
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)