Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Bacteria as sensors: Real-time NMR analysis of extracellular metabolites detects sub-lethal amounts of bactericidal molecules released from functionalized materials

Articolo
Data di Pubblicazione:
2023
Abstract:
Background: Cells exposed to stress factors experience time-dependent variations of metabolite concentration, acting as reliable sensors of the effective concentration of drugs in solution. NMR can detect and quantify changes in metabolite concentration, thus providing an indirect estimate of drug concentration. The quantification of bactericidal molecules released from antimicrobial-treated biomedical materials is crucial to determine their biocompatibility and the potential onset of drug resistance. Methods: Real-time NMR measurements of extracellular metabolites produced by bacteria grown in the presence of known concentrations of an antibacterial molecule (irgasan) are employed to quantify the bactericidal molecule released from antimicrobial-treated biomedical devices. Viability tests assess their activity against E. coli and S. aureus planktonic and sessile cells. AFM and contact angle measurements assisted in the determination of the mechanism of antibacterial action. Results: NMR-derived concentration kinetics of metabolites produced by bacteria grown in contact with functionalized materials allows for indirectly evaluating the effective concentration of toxic substances released from the device, lowering the detection limit to the nanomolar range. NMR, AFM and contact angle measurements support a surface-killing mechanism of action against bacteria. Conclusions: The NMR based approach provides a reliable tool to estimate bactericidal molecule release from antimicrobial materials. General significance: The novelty of the proposed NMR-based strategy is that it i) exploits bacteria as sensors of the presence of bactericidal molecules in solution; ii) is independent of the chemo-physical properties of the analyte; iii) establishes the detection limit to nanomolar concentrations.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Antibacterial; Drug release; Irgasan; Metabolite concentration kinetics; NMR
Elenco autori:
Molinari, Henriette; Iannace, Salvatore; Ragona, LAURA GIUDITTA; Pasini, Mariacecilia; Giovanella, Umberto; Tomaselli, Simona; Kozma, Erika; Pagano, Katiuscia; Scavia, Guido
Autori di Ateneo:
GIOVANELLA UMBERTO
IANNACE SALVATORE
KOZMA ERIKA
PAGANO KATIUSCIA
PASINI MARIACECILIA
RAGONA LAURA GIUDITTA
TOMASELLI SIMONA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/414273
Pubblicato in:
BIOCHIMICA ET BIOPHYSICA ACTA
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)