On Board Calibration System for Millimeter Wave Radiometers Based on Reference Signal Injection
Articolo
Data di Pubblicazione:
2006
Abstract:
This paper presents the architecture of a novel on-hoard calibration system for millimeter-wave radiometers aimed at measuring the Q, U Stokes parameters of the sky emission. This technique requires the injection of differently polarized reference signals, which is carried out by means of a specific component mounted in the antenna-feed system. The presented technique was developed by Cortiglioni et al. for the calibration of the Balloon-borne Radiometers for Sky Polarization Observations radiometers, specifically designed to measure the polarized sky emission by a correlation technique. A procedure for the accurate evaluation of the polarization state of the calibration signals is also reported. Numerical and experimental results are presented for the K alpha-band calibrator in the operational conditions.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
calibration techniques; millimeter waves; radiometers; waveguide components
Elenco autori:
Orta, Renato; Peverini, OSCAR ANTONIO; Virone, Giuseppe; Olivieri, Augusto; Tascone, Riccardo
Link alla scheda completa: