Upgrading a wastewater treatment plant with thermophilic digestion of thermally pre-treated secondary sludge: techno-economic and environmental assessment

Articolo
Data di Pubblicazione:
2015
Abstract:
Nowadays, several technologies and management strategies are proposed for upgrading wastewater treatment plants (WWTPs) in order to improve sludge stabilization or minimize sludge production. In order to make sure that this leads to overall improvements, their techno-economic and environmental performance has to be carefully evaluated. In response to this, the techno-economic and environmental performance was assessed for a considered model reference WWTP upgraded with separate treatment and disposal for primary and secondary sludge to provide guidance to research, policy and investment efforts. This paper departs in an experimental campaign carried out within the EU project "ROUTES" and describes an assessment of an upgrade of a WWTP, involving wet oxidation of primary sludge and thermophilic anaerobic digestion (integrated with thermal hydrolysis pre-treatment) for secondary sludge. The reference plant and the upgrade implied different disposal routes for the resulting sludges: incineration for the stabilized sludge deriving from the reference WWTP; agricultural land application for the secondary stabilized sludge from the upgraded plant and landfilling for the solid residue deriving from the wet oxidation process (as non-hazardous waste). The mass balance carried out for both reference and upgraded WWTPs showed a reduction of total sludge production (up to 45%) for the upgraded WWTP. The additional energy demand of the upgraded solution (รพ22.4 Wh/(PE d), PE: population equivalent) was partially balanced by the electric energy produced by combined heat and power unit installed in the upgraded WWTP (18.08 Wh/(PE d)). The integrated assessment showed that the upgraded solution, although resulting in an increase of WWTP technical complexity, may contribute to environmental and economic advantages. The paper provides guidance in terms of which aspects need a more thorough evaluation when this upgrade is considered in real cases.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Enhanced stabilization process; Thermal hydrolysis; Economic ass; Life cycle assessment; Mass balance; Technical assessment
Elenco autori:
Laera, Giuseppe; Braguglia, CAMILLA MARIA; Mininni, Giuseppe; Gianico, Andrea
Autori di Ateneo:
BRAGUGLIA CAMILLA MARIA
GIANICO ANDREA
LAERA GIUSEPPE
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/299820
Pubblicato in:
JOURNAL OF CLEANER PRODUCTION
Journal
  • Dati Generali

Dati Generali

URL

https://www.sciencedirect.com/science/article/pii/S0959652615004199?via%3Dihub