This work proposes a novel approach to investigate the behavior of single chamber microbial
fuel cells (SCMFCs) based sensors by implementing fluid dynamic simulations to
especially investigate the role of diffusion phenomena. When different flow rates are
applied (i.e., 25 mL/h and 100 mL/h) the electrolyte flows differently into the cell, changing
its speed and the drift-area (Adrift) in which the fluid/electrolyte is directly pushed during
the drift process. Asymmetric squared SCMFCs (a-SCMFCs) ensure optimal fluid motion
thanks to their architecture that maximizes the drift-area. In this work a-SCMFCs are
tested as acetate bio-sensors using carbon paper and carbon felt as anodes. Experimental
results show that the behavior of a-SCMFCs-based sodium acetate biosensors is strongly
influenced by the morphology of both carbon felt and carbon paper-based anodes. We used
fluid dynamics simulations implementing both the drift and the diffusion processes to gain
new information on the behavior of carbon paper and carbon felt anodes. We especially
investigated the role of their porosity, in determining the actual fluid distribution and
analyte concentration inside the device, at the surface of the porous material and into its
volume. We demonstrate that less porous materials, as carbon paper, are more adequate to
be used in single chamber MFC-based biosensors. Indeed they can favor an optimal fluid
motion, especially favoring more uniform diffusion phenomena and interaction between
biofilm and surface than corrugates surfaces, as those characterizing carbon felt, resulting
in a more effective analyte conversion and signal transduction.