Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Dose-response characteristics of insulin action on glucose metabolism: a non-steady-state approach

Articolo
Data di Pubblicazione:
2000
Abstract:
The traditional methods for the assessment of insulin sensitivity yield only a single index, not the whole dose-response curve information. This curve is typically characterized by a maximally insulin-stimulated glucose clearance (Cl(max)) and an insulin concentration at half-maximal response (EC(50)). We developed an approach for estimating the whole dose-response curve with a single in vivo test, based on the use of tracer glucose and exogenous insulin administration (two steps of 20 and 200 mU x min(-1) x m(-2), 100 min each). The effect of insulin on plasma glucose clearance was calculated from non-steady-state data by use of a circulatory model of glucose kinetics and a model of insulin action in which glucose clearance is represented as a Michaelis-Menten function of insulin concentration with a delay (t(1/2)). In seven nondiabetic subjects, the model predicted adequately the tracer concentration: the model residuals were unbiased, and their coefficient of variation was similar to the expected measurement error (approximately 3%), indicating that the model did not introduce significant systematic errors. Lean (n = 4) and obese (n = 3) subjects had similar half-times for insulin action (t(1/2) = 25 +/- 9 vs. 25 +/- 8 min) and maximal responses (Cl(max) = 705 +/- 46 vs. 668 +/- 259 ml x min(-1) x m(-2), respectively), whereas EC(50) was 240 +/- 84 microU/ml in the lean vs. 364 +/- 229 microU/ml in the obese (P < 0.04). EC(50) and the insulin sensitivity index (ISI, initial slope of the dose-response curve), but not Cl(max), were related to body adiposity and fat distribution with r of 0.6-0.8 (P < 0.05). Thus, despite the small number of study subjects, we were able to reproduce information consistent with the literature. In addition, among the lean individuals, t(1/2) was positively related to the ISI (r = 0.72, P < 0.02). We conclude that the test here presented, based on a more elaborate representation of glucose kinetics and insulin action, allows a reliable quantitation of the insulin dose-response curve for whole body glucose utilization in a single session of relatively short duration.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
DEPENDENT DIABETES-MELLITUS; CIRCULATORY MODELS; IMPULSE-RESPONSE; KINETIC-ANALYSIS; BODY
Elenco autori:
Gastaldelli, Amalia
Autori di Ateneo:
GASTALDELLI AMALIA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/173222
Pubblicato in:
AMERICAN JOURNAL OF PHYSIOLOGY: ENDOCRINOLOGY AND METABOLISM
Journal
  • Dati Generali

Dati Generali

URL

http://www.ncbi.nlm.nih.gov/pubmed/10780934?dopt=Citation
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)