Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Trace element determination in seawater by ICP-SFMS coupled with a microflow nebulization/desolvation system

Articolo
Data di Pubblicazione:
2004
Abstract:
Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL-1 and pg mL-1 level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR, m/Dm=300), medium (MR, m/Dm=3,000) and high (HR, m/Dm=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum– maximum in ng mL-1) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004– 0.0018, As 0.69–1.32, Cd 0.031–0.096, Co 0.018–0.065, Cr 0.18–0.46, Cu 0.04–1.58, Fe 0.13–1.63, Mn 0.02– 0.12, Mo 5.97–12.46, Pb 0.007–0.074, Sb 0.033–0.088, U 0.5–1.9, V 0.6–2.5 and Zn 0.16–0.80. Concentration ranges (min–max in ng mL-1) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24–0.61, Ag 0.007– 0.031, As 1.42–2.27, Cd 0.050–0.182, Co 0.440–1.461, Cr 0.15–0.34, Cu 0.81–2.46, Fe 0.25–1.66, Mn 11.6– 31.7, Mo 6.50–10.6, Pb 0.047–0.225, Sb 0.240–0.492, U 1.7–3.3, V 1.3–2.8 and Zn 5.20–21.5. The detection limits range between 0.06 pg mL-1 for Ag and U to 15 pg mL-1 for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Trace elements; Seawater; ICP-SFMS; Desolvation system
Elenco autori:
Capodaglio, Gabriele; Barbante, Carlo; Cescon, Paolo; Turetta, Clara; Cozzi, Giulio
Autori di Ateneo:
BARBANTE CARLO
COZZI GIULIO
TURETTA CLARA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/48048
Pubblicato in:
ANALYTICAL & BIOANALYTICAL CHEMISTRY (PRINT)
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)