Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study

Articolo
Data di Pubblicazione:
2015
Abstract:
Purpose: An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs.,Methods: This was a multicenter study enrolling 469 consecutive patients. Single- versus dual-coil leads and cathodal versus anodal polarity were evaluated at defibrillation testing. In all cases, the value of the energy for the first shock was set to 20 J less than the maximum energy deliverable from the device.,Results: A total of 469 patients underwent defibrillation testing: 158 (34 %) had dual-coil and 311 (66 %) had single-coil lead systems configuration, 254 (54 %) received anodal shock and 215 (46 %) received cathodal shock. In 35 (7.4 %) patients, the shock was unsuccessful. No significant differences in the outcome of defibrillation testing using single- versus dual-coil lead were observed but the multivariate analysis showed an increased risk of shock failure using cathodal shock polarity (OR 2.37, 95 % CI 1.12-5.03).,Conclusions: Both single- and dual-coil transvenous ICD lead systems were associated with high rates of successful ICD implantation, and we found no significant differences in ventricular arrhythmias interruption between the two ICD lead systems configuration. Instead, anodal defibrillation was more likely to be successful than cathodal defibrillation.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Anodal shock polarity; Cathodal shock polarity; Dual-coil lead; Implantable cardioverter defibrillator; Single-coil lead
Elenco autori:
Minicuci, Nadia
Autori di Ateneo:
MINICUCI NADIA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/294599
Pubblicato in:
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY (PRINT)
Journal
  • Dati Generali

Dati Generali

URL

http://www.ncbi.nlm.nih.gov/pubmed/25690336
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)