Abstract:
As well known the ETICS are diffusely used both for energy saving and thermal insulation reasons. They have been applied recently in wood buildings and in regions of southern Europe too due to green building and sustainability reasons. ITC-CNR has tested a lot of building materials and developed good knowledge about reaction to fire since the 1980 and currently, ETICS fixed directly to particle wood panels have been investigated with several SBI tests. In the case study are presented the main factors that can influence the fire reaction results when applied on wood structure are highlighted: the thickness of the insulating material, the presence of accidental damage, the flame attack from the inside. From the results obtained by tests on samples prepared with simulated accidental damages and fire from inside, some considerations are made about the hazard due to this specific construction technology and others on limits of the type of actually used standards product classification.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
Reaction to fire; Etics; experimental tests
Elenco autori:
Galimberti, Vittorio; Bonati, Antonio
Link alla scheda completa: