Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Value of semiquantitative analysis for clinical reporting of 123I-2-?-carbomethoxy-3?-(4-iodophenyl)-N-(3-fluoropropyl) nortropane SPECT studies

Articolo
Data di Pubblicazione:
2013
Abstract:
Clinical 123I-2-b-carbomethoxy-3b-(4-iodophenyl)-N-(3-fluoropropyl) nortropane (123I-FP-CIT) SPECT studies are commonly performed and reported using visual evaluation of tracer binding, an inherently subjective method. Increased objectivity can potentially be obtained using semiquantitative analysis. In this study, we assessed whether semiquantitative analysis of 123I-FP-CIT tracer binding created more reproducible clinical reporting. A secondary aim was to determine in what form semiquantitative data should be provided to the reporter. Methods: Fifty-four patients referred for the assessment of nigrostriatal dopaminergic degeneration were scanned using SPECT/CT, followed by semiquantitative analysis calculating striatal binding ratios (SBRs) and caudate-to-putamen ratios (CPRs). Normal reference values were obtained using 131 healthy controls enrolled on a multicenter initiative backed by the European Association of Nuclear Medicine. A purely quantitative evaluation was first performed, with each striatum scored as normal or abnormal according to reference values. Three experienced nuclear medicine physicians then scored each striatum as normal or abnormal, also indicating cases perceived as difficult, using visual evaluation, visual evaluation in combination with SBR data, and visual evaluation in combination with SBR and CPR data. Intra- and interobserver agreement and agreement between observers and the purely quantitative evaluation were assessed using k-statistics. The agreement between scan interpretation and clinical diagnosis was assessed for patients with a postscan clinical diagnosis available (n 5 35). Results: The physicians showed consistent reporting, with a good intraobserver agreement obtained for the visual interpretation (mean k 6 SD, 0.95 6 0.029). Although visual interpretation of tracer binding gave good interobserver agreement (0.80 6 0.045), this was improved as SBRs (0.86 6 0.070) and CPRs (0.95 6 0.040) were provided. The number of striata perceived as difficult to interpret decreased as semiquantitative data were provided (30 for the visual interpretation; 0 as SBR and CPR values were given). The agreement between physicians' interpretations and the purely quantitative evaluation showed that readers used the semiquantitative data to different extents, with a more experienced reader relying less on the semiquantitative data. Good agreement between scan interpretation and clinical diagnosis was seen. Conclusion: A combined approach of visual assessment and semiquantitative analysis of tracer binding created more reproducible clinical reporting of 123I-FP-CIT SPECT studies. Physicians should have access to both SBR and CPR data to minimize interobserver variability.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
[object Object; Dopamine transporter; Observer variability; Semiquantification
Elenco autori:
Pagani, Marco
Autori di Ateneo:
PAGANI MARCO
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/322000
Pubblicato in:
THE JOURNAL OF NUCLEAR MEDICINE (1978)
Journal
  • Dati Generali

Dati Generali

URL

http://www.scopus.com/record/display.url?eid=2-s2.0-84877116997&origin=inward
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)