Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization (vol 01, 039, 2019)

Articolo
Data di Pubblicazione:
2019
Abstract:
We designed, fabricated, and characterized four arrays of horn-coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) eect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is lled with diraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the ight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 mK. The measured average resonator Qs are 1:7104, 7:0103, 1:0104, and 1:0 104 for the 150, 250, 350, and 460 GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 rad/pW, 1.5 rad/pW, 2.1 rad/pW, and 2.1 rad/pW; the electrical noise equivalent powers are 45aW/pHz, 160aW/pHz, 80aW/pHz, and 140aW/pHz, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The mea- sured NETRJs are 200K:ps, 240 Kps, 240 Kps, and 340 Kps, at 12 Hz; under 78, 88, 92, and 90mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO dierential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
CMBR detectors; CMBR experiments; Sunyaev-Zeldovich effect
Elenco autori:
Colantoni, Ivan; Castellano, MARIA GABRIELLA; Pettinari, Giorgio
Autori di Ateneo:
COLANTONI IVAN
PETTINARI GIORGIO
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/390824
Pubblicato in:
JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS
Journal
  • Dati Generali

Dati Generali

URL

https://doi.org/10.1088/1475-7516/2019/01/039
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)