Data di Pubblicazione:
2015
Abstract:
We report on a quartz-enhanced photoacoustic (QEPAS) gas sensing system for hydrogen sulphide (H2S) detection. The system architecture is based on a custom quartz tuning fork (QTF) optoacoustic transducer with a novel geometry and a quantum cascade laser (QCL) emitting 1.1 mW at a frequency of 2.913 THz. The QTF operated on the first flexion resonance frequency of 2871 Hz, with a quality factor Q = 17,900 at 20 Torr. The tuning range of the available QCL allowed the excitation of a H2S rotational absorption line with a line-strength as small as S = 1.13.10-22 cm/mol. The measured detection sensitivity is 30 ppm in 3 seconds and 13 ppm for a 30 seconds integration time, which corresponds to a minimum detectable absorption coefficient ?min = 2.3.10-7 cm-1 and a normalized noise-equivalent absorption NNEA = 4.4.10-10 W.cm-1.Hz-1/2, several times lower than the values previously reported for near-IR and mid-IR H2S QEPAS sensors.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
-
Elenco autori:
Vitiello, MIRIAM SERENA
Link alla scheda completa:
Pubblicato in: