Hydrocarbons as Substitutes for Halogenated Refrigerants in Refrigerating Systems
Contributo in Atti di convegno
Data di Pubblicazione:
1994
Abstract:
ABSTRACT The paper deals with the use of R-290/600a (50/50) and R-600a, that are now
considered as alternative to R-134a to substitute R-12 in domestic refrigeration. A theoretical
analysis of the mixture performance shows that both hydrocarbon refrigerants may be used.
Tests of certain hermetic compressors confrrm that the mixture can be used both for old and
new equipment, while the isobutane must be used for new equipment only.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Elenco autori:
Bobbo, Sergio; Camporese, Roberto
Link alla scheda completa: