Data di Pubblicazione:
2013
Abstract:
A superconducting coil system is actually complicated by the distributed parameters, e.g. the distributed mutual inductance among turns and the distributed capacitance between adjacent conductors. In this paper, such a complicated system was modeled with a reasonably simplified circuit network with lumped parameters. Then, a detailed circuit analysis was conducted to evaluate the possible voltage transient in the coil circuit. As a result, an appropriate (minimum) snubber capacitance for the Switching Network Unit, which is a fast high voltage generation circuit in JT-60SA, was obtained.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Jt-60SA; Power supply; PSIM; Snubber; Transient voltage
Elenco autori:
Gaio, Elena
Link alla scheda completa:
Pubblicato in: