Calibration procedure for focal plane array cameras and noise equivalent material loss for quantitative thermographic NDT

Articolo
Data di Pubblicazione:
1997
Abstract:
In this paper a complete procedure is proposed for the calibration of a focal plane array in quantitative infrared nondestructive testing (NDT). This procedure includes vignetting correction and gray level conversion into temperature. A noise analysis is also presented in the context of pulsed infrared thermography applied to NDT. In this analysis, we introduce a new parameter, the noise equivalent material loss (NEML). The NEML is a global figure of merit which allows the comparison of different experimental setups for infrared pulsed thermography. Theory, experimental validation of the proposed concepts, and comparison with a few infrared scanning thermal imagers are presented as well.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
corrosion assessment; focal plane array; noise analysis; nondestructive testing; pulsed infrared thermography; quantitative defect characterization; thermal imager; thermal wave imaging
Elenco autori:
Marinetti, Sergio
Autori di Ateneo:
MARINETTI SERGIO
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/237886
Pubblicato in:
MATERIALS EVALUATION
Journal