The ongoing experimental campaigns of RFX-mod are performed setting operational parameters at the
nominal or exceeding design values of the experiment. Compressive forces up to 11MN are produced
by high magnetizing currents that reach values up to 50 kA. These forces heavily load the mechanical
structure of RFX-mod and their effects are measured and monitored in order to assess the expected
structural response and machine reliability during operation.
Mechanical strains and relative displacements are real time measured during each experimental pulse
by 48 strain gauges located on 12 mechanical struts and 16 potentiometers positioned between the
toroidal assembly and the support mechanical structure.
The strains in the most stressed components are measured by means of 24 half bridge gauges preliminarily
calibrated.
Particular care has been given to sensor choices and installation in order to minimize signal noises
induced by the electrical and magnetic fields. The residual noises have been further reduced by proper
sampling frequency and averaging techniques.
The strains measured on the struts are then post-processed to calculate the resultant forces and bending
moments, while the displacement measurements give an estimate of the overall stiffness of the
mechanical structure.
The measured forces and displacements are shown per toroidal locations and as a function of the
current intensity, so verifying the uniform sharing of forces among the different struts and the proper
square law correlation with the magnetizing current intensity.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Mechanical measurements; Strain gauges; Potentiometers; Relative displacements
Elenco autori:
Taliercio, Cesare; Ghiraldelli, Raffaele; Fincato, Michele; DALLA PALMA, Mauro; Zaccaria, Pierluigi; Marchiori, Giuseppe