AN OPTICAL FIBRE CABLE FOR DISTRIBUTED PRESSURE SENSING WITH HIGH RESOLUTION AND SENSITIVITY

Contributo in Atti di convegno
Data di Pubblicazione:
2020
Abstract:
In this work, we present an optical fibre cable for distributed pressure sensing employing standard single-mode fibres. The cable can be interrogated with a distributed strain sensing interrogator, either based on Rayleigh or Brillouin scattering. By using an optical frequency domain reflectometer with 1 ?? of strain resolution on a cable prototype, we found that the spatial resolution is approx. 8.5 cm, and the pressure resolution and accuracy are approximately 5 Pa and 10 hPa, respectively.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
Optical fibre cable; distributed pressure measurements
Elenco autori:
Schenato, Luca; Pasuto, Alessandro
Autori di Ateneo:
PASUTO ALESSANDRO
SCHENATO LUCA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/384632