Data di Pubblicazione:
2011
Abstract:
The problem of evaluating dissipative effects in Josephson junctions loaded by transmission lines is reexamined, for either the symmetric or the asymmetric case, with particular consideration of the time domain in which the interaction between junction and load system occurs.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Josephson junctions
Elenco autori:
Cacciari, Ilaria; Moretti, Paolo; Ranfagni, Anedio
Link alla scheda completa:
Pubblicato in: