Data di Pubblicazione:
2017
Abstract:
The JET tangential gamma-ray spectrometer is undergoing an extensive upgrade in order to make it compatible with the forthcoming deuterium-tritium (DT) experiments. The paper presents the results of the design for the main components for the upgrade of the spectrometer beam-line: tandem collimators, gamma-ray shields, and neutron attenuators. The existing tandem collimators will be upgraded by installing two additional collimator modules. Two gamma-ray shields will define the gamma-ray field of-view at the detector end of the spectrometer line-of-sight. A set of three lithium hydride neutron attenuators will be used to control the level of the fast neutron flux on the gamma-ray detector. The design of the upgraded spectrometer beam-line has been supported by extensive radiation (neutron and photon) transport calculations using both large volume and point radiation sources. (C) 2017 The Authors. Published by Elsevier B.V.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Tokamak; Diagnostics; Gamma-rays; Gamma-ray spectrometer; Neutron attenuators
Elenco autori:
Nocente, Massimo; Gorini, Giuseppe; Tardocchi, Marco
Link alla scheda completa:
Pubblicato in: