In this paper we discuss the linearity response of the Planck-LFI receivers, with particular
reference to signal compression measured on the 30 and 44 GHz channels. In the article
we discuss the various sources of compression and present a model that accurately describes data
measured during tests performed with individual radiomeric chains. After discussing test results
we present the best parameter set representing the receiver response and discuss the impact of non
linearity on in-flight calibration, which is shown to be negligible.