Data di Pubblicazione:
2013
Abstract:
The distribution and elimination of a bolus of glucose injected during hemodialysis (HD) was examined using a distributed double-pool regional blood flow model. Intracorporeal glucose disposal was assumed as insulin-independent (?) in the central high-flow compartment comprising blood, brain, and internal organs, including pancreatic insulin secretion (a, C1) and hepatic insulin clearance (?). Insulin-dependent (?) glucose utilization was allocated to the low-flow system comprising muscle, skin, and bone. This model was compared with a compact single-pool model using the same model parameters except for the distribution volume (V). Six parameters (C1, a, ?, ?, ?, and V) were identified from data obtained in seven nondiabetic patients (59-115 kg). The fraction Fd of glucose removed by HD significantly (p < 0.05) correlated with baseline glucose concentration Cg,0 (5.561
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Blood flow modeling; Distribution volume; Extracorporeal systems; Fluid management; Glucose concentration; Insulin kinetics; Insulin secretion; Model parameters; Dialysis; Hemodialyzers; Hemodynamics; Insulin; Lakes; Glucose; glucose; insulin; adult; aged; article; blood flow; brain; clinical article; controlled study; diabetic patient; distribution volume; extracorporeal circulation; female; fluid therapy; glucose blood level; glucose transport; glucose utilization; hemodialysis; hemodialysis patient; human; insulin blood level; insulin clearance; insulin dependent diabetes mellitus; insulin release; liver; male; parameters; priority journal; systemic circulation; ultrafiltration
Elenco autori:
Thomaseth, Karl
Link alla scheda completa:
Pubblicato in: