Influence of electron traps on charge collection efficiency in GaAs radiation detectors

Academic Article
Publication Date:
1994
abstract:
This paper deals with the interpretation of the charge-collection efficiency for minimum ionizing particles in terms of electron traps in semi-insulating liquid encapsulated Czochralski gallium arsenide detectors fabricated with thicknesses of 80, 200, and 300 micron. The results, obtained within the context of the RD-8 project, show that low values of charge-collection efficiency cannot be ascribed primarily to primarily to the presence of high concentrations of EL2 defects. Possible ways of increasing the charge-collection efficiency are briefly addressed.
Iris type:
01.01 Articolo in rivista
Keywords:
GaAs; electron traps; charge collection
List of contributors:
Frigeri, Cesare; Zanotti, Lucio
Handle:
https://iris.cnr.it/handle/20.500.14243/140897
Published in:
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT