Comb-calibrated sub-Doppler spectroscopy with an external-cavity quantum cascade laser at 7.7 um

Articolo
Data di Pubblicazione:
2019
Abstract:
We study the frequency noise and the referencing to a near-infrared frequency comb of a widely tunable external-cavity quantum-cascade-laser that shows a relatively narrow free-running emission linewidth of 1.7 MHz. The frequency locking of the laser to the comb further narrows its linewidth to 690 kHz and enables sub-Doppler spectroscopy on an NO transition of the ? band near 7.7 ?m with sub-MHz resolution and absolute frequency calibration. The combined uncertainty on the measured transition center is estimated to be less than 50 kHz.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Frequency comb; Precision spectroscopy; Quantum-cascade-laser
Elenco autori:
Laporta, Paolo; Marangoni, MARCO ANDREA; Gatti, Davide; Lamperti, Marco
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/367127
Pubblicato in:
OPTICS EXPRESS