Publication Date:
2013
abstract:
In this work, calculations and preliminary experimental data for determining the optimal condition for the selective bio-functionalization of magnetic tunneling junction (MTJ)-based biosensors are presented. Results on the detection of biomolecular recognition events employing MTJ-based sensor and magnetic beads are presented and interpreted through calculations, taking into account the dependence of the signal on the distribution of the beads with respect to the sensor. Furthermore, it is demonstrated by calculations that a significant increase in the sensor sensitivity and quantification capability can be achieved by selectively bio-functionalizing an area which corresponds to the sensor active area.
Iris type:
01.01 Articolo in rivista
List of contributors:
Sola, Laura; Bagnati, Marta; Cretich, Marina; Damin, Francesco; Chiari, Marcella