Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Internally consistent geothermometers for garnet peridotites and pyroxenites

Academic Article
Publication Date:
2010
abstract:
Mutual relationships among temperatures estimated with the most widely used geothermometers for garnet peridotites and pyroxenites demonstrate that the methods are not internally consistent and may diverge by over 200°C even in well-equilibrated mantle xenoliths. The Taylor (N Jb Min Abh 172:381-408, 1998) two-pyroxene (TA98) and the Nimis and Taylor (Contrib Mineral Petrol 139:541-554, 2000) single-clinopyroxene thermometers are shown to provide the most reliable estimates, as they reproduce the temperatures of experiments in a variety of simple and natural peridotitic systems. Discrepancies between these two thermometers are negligible in applications to a wide variety of natural samples (<30°C). The Brey and Kohler (J Petrol 31:1353-1378, 1990) Ca-in-Opx thermometer shows good agreement with TA98 in the range 1,000-1,400°C and a positive bias at lower T (up to +90°C, on average, at TTA98 = 700°C). The popular Brey and Kohler (J Petrol 31:1353-1378, 1990) two-pyroxene thermometer performs well on clinopyroxene with Na contents of ca. 0.05 atoms per 6-oxygen formula, but shows a systematic positive bias with increasing NaCpx (+150°C at NaCpx = 0.25). Among Fe-Mg exchange thermometers, the Harley (Contrib Mineral Petrol 86:359-373, 1984) orthopyroxene-garnet and the recent Wu and Zhao (J Metamorphic Geol 25:497-505, 2007) olivine-garnet formulations show the highest precision, but systematically diverge (up to ca. 150°C, on average) from TA98 estimates at T far from 1,100°C and at T<1,200°C, respectively; these systematic errors are also evident by comparison with experimental data for natural peridotite systems. The older O'Neill and Wood (Contrib Mineral Petrol 70:59-70, 1979) version of the olivine-garnet Fe-Mg thermometer and all popular versions of the clinopyroxene-garnet Fe-Mg thermometer show unacceptably low precision, with discrepancies exceeding 200°C when compared to TA98 results for well-equilibrated xenoliths. Empirical correction to the Brey and Ko¨hler (J Petrol 31:1353-1378, 1990) Ca-in-Opx thermometer and recalibration of the orthopyroxene-garnet thermometer, using well-equilibrated mantle xenoliths and TA98 temperatures as calibrants, are provided in this study to ensure consistency with TA98 estimates in the range 700-1,400°C. Observed discrepancies between the new orthopyroxene-garnet thermometer and TA98 for some localities can be interpreted in the light of orthopyroxene-garnet Fe3+ partitioning systematics and suggest localized and lateral variations in mantle redox conditions, in broad agreement with existing oxybarometric data. Kinetic decoupling of Ca-Mg and Fe-Mg exchange equilibria caused by transient heating appears to be common, but not ubiquitous, near the base of the lithosphere.
Iris type:
01.01 Articolo in rivista
Keywords:
Thermobarometry; Mantle xenoliths; Garnet peridotites; Garnet pyroxenites
List of contributors:
Nimis, Paolo
Handle:
https://iris.cnr.it/handle/20.500.14243/14710
Published in:
CONTRIBUTIONS TO MINERALOGY AND PETROLOGY
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)