Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Soil CO2 flux baseline in Planchón - Peteroa Volcanic Complex, Southern Andes, Argentina - Chile

Articolo
Data di Pubblicazione:
2021
Abstract:
The Planchon´- Peteroa Volcanic Complex exhibits two active degassing areas: Peteroa crater, PC, and peripheral hydrothermal areas, analyzed in three sampling sites, namely Valle Banos~ del Azufre, VBA, Valle del Pen~on, ´ VP and Valle Valenzuela, VZ. This prospective study was designed to investigate the soil diffuse emissions of CO2 at this volcanic complex. The survey consisted of 560 measurements of CO2 soil diffuse flux and temperature carried out at PC, VBA, VP. The results of this work show that diffuse CO2 is emitted at PC through two welldefined diffuse degassing structures and flux distribution that can be modeled by combining two log-normal populations. Here, the main source of soil CO2 is a shallow aquifer recharged by steam condensation and meteoric fluids that interact with rising magmatic gases. The carbon isotopic signature reveals that CO2 diffuse degassing is affected by secondary soil processes during its ascent. The total diffuse CO2 output at the surveyed area of PC, which covers 77,000 m2 around the crater fumarolic field, is 6.49 ± 0.32 td- 1 . Soil diffuse emissions at the hydrothermal peripheral sites, VBA and VP, were studied covering a total area of 590,000 ? m2 . These emissions are characterized by poorly defined diffuse degassing structures and flux distributions that can be modeled by combining three log-normal populations, which suggest that multiple sources feed CO2 diffuse emissions. In concordance, the isotopic analysis also suggests a mixed source of CO2 and degassing affected by secondary processes that modify the original isotope composition. CO2 soil degassing at VZ shows a clear relation with the vegetated areas of the soil. The minimum endogenous CO2 output estimation here proposed for the Planchon´- Peteroa Volcanic Complex is that of PC, -6.5t d- 1 . The thermal energy release was computed for PC, and the estimation is 2.57 ± 0.53 MW.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
CO2 diffuse degassing; sources; Plan
Elenco autori:
Tassi, Franco; Venturi, Stefania
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/428770
Pubblicato in:
JOURNAL OF SOUTH AMERICAN EARTH SCIENCES
Journal
  • Dati Generali

Dati Generali

URL

https://www.journals.elsevier.com/journal-of-south-american-earth-sciences
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)