Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Integrating printed microfluidics with silicon photomultipliers for miniaturised and highly sensitive ATP bioluminescence detection

Academic Article
Publication Date:
2018
abstract:
Bioluminescence has been widely used for important biosensing applications such as the measurement of adenosine triphosphate (ATP), the energy unit in biological systems and an indicator of vital processes. The current technology for detection is mainly based on large equipment such as readers and imaging systems, which require intensive and time-consuming procedures. A miniaturised bioluminescence sensing system, which would allow sensitive and continuous monitoring of ATP, with an integrated and low-cost disposable microfluidic chamber for handling of biological samples, is highly desirable. Here, we report the design, fabrication and testing of 3D printed microfluidics chips coupled with silicon photomultipliers (SiPMs) for high sensitive real-time ATP detection. The 3D microfluidic chip reduces reactant consumption and facilitates solution delivery close to the SiPM to increase the detection efficiency. Our system detects ATP with a limit of detection (LoD) of 8 nM and an analytical dynamic range between 15 nM and 1 µM, showing a stability error of 3%, and a reproducibility error below of 20%. We demonstrate the dynamic monitoring of ATP in a continuous-flow system exhibiting a fast response time, ~4 s, and a full recovery to the baseline level within 17 s. Moreover, the SiPM-based bioluminescence sensing system shows a similar analytical dynamic range for ATP detection to that of a full-size PerkinElmer laboratory luminescence reader.
Iris type:
01.01 Articolo in rivista
Keywords:
ATP bioluminescence detection; Continuous flow monitoring; Disposable 3D Lab-on-chip; Miniaturised sensing system; Silicon Photomultiplier
List of contributors:
Santangelo, MARIA FRANCESCA; Libertino, Sebania
Authors of the University:
LIBERTINO SEBANIA
Handle:
https://iris.cnr.it/handle/20.500.14243/335956
Published in:
BIOSENSORS & BIOELECTRONICS
Journal
  • Overview

Overview

URL

https://doi.org/10.1016/j.bios.2017.07.055
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)