Saturated Pressure Measurements of cis-1-Chloro-2,3,3,3- tetrafluoropropene (R1224yd (Z)) Saturation Pressure

Academic Article
Publication Date:
2020
abstract:
Cis-1-chloro-2,3,3,3-tetrafluoropropene (R1224yd (Z)) is an interesting alternative nonflammable refrigerant suggested for use in centrifugal chillers, binary cycle, organic Rankine cycle (ORC), and high-temperature heat pumps, as well as blowing agent, for its very low ozone depleting potential (ODP), that is almost zero, and a global warming potential (GWP) lower than 1. Three sets of data have already been published in the literature. Herein, 31 new saturated pressure data for temperatures between 293.15 and 353.15 K are presented, down to temperatures 17 K lower than the previous data. These results are fitted to Wagner-type equation and compared with literature data.
Iris type:
01.01 Articolo in rivista
Keywords:
refrigerant; vapour pressure; R1224yd (Z)
List of contributors:
Bet, Anna; Bobbo, Sergio; Fedele, Laura; Scattolini, Mauro
Authors of the University:
BOBBO SERGIO
FEDELE LAURA
SCATTOLINI MAURO
Handle:
https://iris.cnr.it/handle/20.500.14243/424083
Published in:
JOURNAL OF CHEMICAL AND ENGINEERING DATA
Journal
  • Overview

Overview

URL

http://www.scopus.com/record/display.url?eid=2-s2.0-85088137461&origin=inward
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)