Calorimeter Design for Neutral Beam Injector of DTT - Thermo-hydraulic Analysis
Contributo in Atti di convegno
Data di Pubblicazione:
2020
Abstract:
The main steps in the development of the calorimeter design for the Neutral Beam Injector
(NBI) of Divertor Tokamak Test (DTT, a new tokamak whose construction is starting in
Frascati, Italy) are presented. The beam power absorbed by the calorimeter panels is removed
by the pressurized water flowing through the cooling pipes drilled into the panel structure. The
heat transfer to the coolant is enhanced by twisted tape inserts. The design and dimensions of
the panels and cooling pipes are based on the thermal-hydraulic optimisation using detailed
Computational Fluid Dynamics (CFD) analyses.
The analysis considers local thermal-hydraulic parameters, such as maximum
temperature of the panels and of the coolant, coolant pressure drop and geometric constraints
like panel inclination angle and available space. The beam power of the DTT NBI takes into
account the beam imprints and power distributions in the beam core and in the beam halo, which
are modelled by superposition of Gaussian functions. In CFD simulations the coupled solidfluid heat transfer problem is solved. Main design choices and optimisation are determined by
minimising the maximum temperature of the panel structure and of the near-wall temperature
of the coolant.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
Divertor Test Tokamak; DTT; Neutral Beam Injector; NBI; Calo; ITER; Neutral Beam Test Facility; NBTF; Thermo-hydraulic
Elenco autori:
Agostinetti, Piero
Link alla scheda completa: