Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Perturbations produced by electrospray ionization mass spectrometry in the speciation of aluminium(III)/1,6-dimethy1-4-hydroxy-3-pyridinecarboxylate aqueous solutions

Articolo
Data di Pubblicazione:
2010
Abstract:
Electrospray ionization mass spectrometry (ESI-MS) is very often employed to study metal/ligand equilibria in aqueous solution. However, the ionization process can introduce perturbations which affect the speciation results in an unpredictable way. It is necessary to identify these perturbations in order to correctly interpret the ESI-MS speciation results. Aluminium(III)/1,6-dimethy1-4-hydroxy-3-pyridinecarboxylate (DQ716) aqueous solutions at various pH were analysed by ESI-MS, and speciation results were compared with those obtained by equilibrium techniques. Differences observed were both qualitative and quantitative. The ESI-MS spectral changes due to different settings of the following instrumental parameters were analyzed: the solution flow rate (F-S), the nebulizer gas flow rate (F-G), the potential applied at the entrance capillary (E-C), and the temperature of the drying gas (T-G). The effects produced by F-S and E-C on the spectra strongly suggest the key role of surface activity in determining the relative fraction of the ions reaching the detector. The experimental effects of F-S and T-G were interpreted considering the presence of at least two reactions in the gas phase and a dimerization occurring in the droplets. These perturbations cannot be generalized because they appear to be chemical system-related and instrument-dependent. Therefore, the identification of perturbations is a required task for any metal-ligand equilibrium study performed by ESI-MS. Our results indicate that perturbations can be identified by evaluating the effects produced in the spectra by a change of instrumental parameters. Copyright (C) 2010 John Wiley & Sons, Ltd.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
LIGAND SOLUTION EQUILIBRIA; INSTRUMENTAL PARAMETERS; COMPLEXES; ESI; MS
Elenco autori:
Traldi, Pietro
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/71607
Pubblicato in:
RCM. RAPID COMMUNICATIONS IN MASS SPECTROMETRY
Journal
  • Dati Generali

Dati Generali

URL

http://onlinelibrary.wiley.com/doi/10.1002/rcm.4457/abstract
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)