Thermal integration of a SOFC power generator and a Na-NiCl2 battery for CHP domestic application

Academic Article
Publication Date:
2017
abstract:
In this study the integration of a Solid Oxide Fuel Cell (SOFC) prime mover and a high temperature electrochemical Sodium Nickel Chloride (SNC) battery as storage has been investigated. The aim is to fulfil a domestic user energy demand and to reduce the primary energy consumption in comparison with a reference conventional scenario, thereby, to enhance the total efficiency in mu-CHP (Combined Heat and Power) application on a yearly basis. A realistic operational sequence of the SOFC-battery integration has been calculated using simple logic conditions. Both thermal and electric integration have been considered, where the innovative thermal integration has been proposed in order to exploit the SOFC residual heat for the battery stand-by feeding. The key advantage of this system architecture is that the SOFC is operated without major load variations close to constant load, resulting in longer lifetime and thus reducing total costs of operation. The thermal integration provides additional advantages, as calculated in this study. Eventually, a comparison with alternative mu-CHP technologies has been carried out, highlighting the potential of the system based on the SOFC. Benefits are mainly shown in terms of primary energy savings and admissible costs. (C) 2016 Elsevier Ltd. All rights reserved.
Iris type:
01.01 Articolo in rivista
Keywords:
SOFC; batteries; hybrid; SOFC; Micro CHP; Energy storage; Sodium Nickel Chloride batteries; SOFC; SOFC; SOFC MicroCHP; SOFC; Micro CHP
List of contributors:
Antonucci, Vincenzo; Ferraro, Marco; Sergi, Francesco; Brunaccini, Giovanni
Authors of the University:
BRUNACCINI GIOVANNI
FERRARO MARCO
SERGI FRANCESCO
Handle:
https://iris.cnr.it/handle/20.500.14243/318042
Published in:
APPLIED ENERGY