High-throughput spatial resolved tests over planar model catalyst libraries: A novel reactor approach.
Academic Article
Publication Date:
2009
abstract:
The development of two different in-flow scanning reactors that could be successfully used for testing the activity of planar catalysts are presented. The first one, which allows stepwise scans, is composed by a reactor probe which is sealed over the planar system using a Teflon or
Viton mask that also defines the reaction chamber volume. The presence of the sealing mask causes various problems that are solved with the
second prototype. In this reactor a controlled leakage system is used instead of the Viton seal, which allows continuous scanning test on a
reduced circular area (12.5 mm(2)). In this paper the results of preliminary tests over palladium based catalysts are presented in order
to discuss the applicability of both reactors.
Iris type:
01.01 Articolo in rivista
Keywords:
HIGH-THROUGHPUT; PLANAR CATALYST; CATALYST LIBRARIES; MICRO REACTOR; PALLADIUM FILM
List of contributors:
DAL SANTO, Vladimiro; Marelli, Marcello; Psaro, Rinaldo
Published in: