Data di Pubblicazione:
2016
Abstract:
This study investigates on the efficiency of integrated reformer-MCFC system. Performances
of a Ni catalyst working under steam reforming conditions of three different biofuels
(biogas, ethanol and glycerol) are experimentally evaluated. Reformers outlet stream
were applied as fuel for a MCFC stack in order to estimate the total integrated system
efficiencies.
It is found that the large amount of heat (20%e54% of the inlet fuel e LHV basis) is
employed for the reforming of the biofuel during the heating phase of inlet stream to the
reforming operative temperature. Moreover, among the examined biofuels the highest
amount of externally supplied energy (~79% of the inlet fuel e LHV basis) is wasted in the
fuel processor unit for the steam reforming of ethanol, mostly due to the high amount of
the water required (S/C ΒΌ 4.2 mol/mol). Finally, it is also found that the combined biogas
reformer-MCFC system is exhibited the highest electrical efficiency (76%).
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Biogas; Ethanol; Glycerol; MCFC
Elenco autori:
Maisano, Susanna; Zafarana, Giovanni; Freni, Salvatore; Chiodo, Vitaliano; Urbani, Francesco
Link alla scheda completa:
Pubblicato in: