Data di Pubblicazione:
2021
Abstract:
Extreme conditions are predicted for the next generation devices as DEMO that can cause
severe damages to the plasma facing components (PFCs). Possible benefits could arise from
the adoption of Alternative divertor Configurations (ADCs) [1,2] which are currently under
investigation. In particular, the Double Null configuration represents one of the possible
candidates, as shown for instance in numerical studies performed with SOLDEGE2DEIRENE
[3]. Drifts can play an important role in determining the actual Scrape-Off Layer
(SOL) conditions by acting on the plasma transport and detachment as seen in the present
device[4-7]. In this contribution, we will discuss the role of the drifts in a Connected Double
Null (CDN) configuration in DTT (Divertor Test Tokamak) [8] by analyzing the change in the
divertor plasma conditions and the effect on the power asymmetry.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
DTT; DTT Double Null configuration; SOL plasma
Elenco autori:
Innocente, Paolo
Link alla scheda completa:
Titolo del libro:
47th EPS Conference on Plasma Physics 21 - 25 June 2021
Pubblicato in: