  1. Outputs

Asymmetry of SPECT Perfusion Image Patterns as a Diagnostic Feature for Alzheimer's Disease. Medical Image Computing and Computer-Assisted Intervention -

Academic Article
Publication Date:
2006
abstract:
In this paper we propose a new diagnostic feature for Alzheimer's Disease (AD) which is based on assessment of the degree of inter-hemispheric asymmetry using Single Photon Emission Computed Tomography (SPECT). The asymmetry measure used represents differ- ences in 3D perfusion image patterns in the cerebral hemispheres. We start from the simplest descriptors of brain perfusion such as the mean intensity within pairs of brain lobes, gradually increasing the resolution up to five-dimensional co-occurrence matrices. Evaluation of the method was performed using SPECT scans of 79 subjects including 42 patients with clinical diagnosis of AD and 37 controls. It was found that combina- tion of intensity and gradient features in co-occurrence matrices captures significant differences in asymmetry values between AD and normal con- trols (p < 0.00003 for all cerebral lobes). Our results suggest that the asymmetry feature is useful for discriminating AD patients from normal controls as detected by SPECT.
Iris type:
01.01 Articolo in rivista
List of contributors:
Pagani, Marco
Authors of the University:
PAGANI MARCO
Handle:
https://iris.cnr.it/handle/20.500.14243/64769
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)