Publication Date:
2018
abstract:
The non-local expression proposed by Luciani-Mora-Virmont is implemented in a one dimensional fluid model for the scrape-off layer. Analytical solutions for heat equation are discussed as well as the impact of sheath boundary conditions on the continuity of the temperature profile. The non-local heat flux is compared to the Spitzer-Härm heat flux for different collisionality.
Iris type:
01.01 Articolo in rivista
Keywords:
heat conduction; non-local transport; plasma physics
List of contributors:
Livi, Roberto; DI CINTIO, Pierfrancesco; Lepri, Stefano