Publication Date:
2007
abstract:
The new multichannel Martin-Puplett interferometer for Electron Cyclotron Emission (ECE) measurements has been working at JET from the 2006 experimental campaign. After the installation, the interferometer has been extensively studied using radiation sources of different wavelengths and coherence. This paper deals with the detailed description of the installation tests performed in the millimeter wave range, and discusses the features and the limits of the different measurements performed.
Iris type:
04.01 Contributo in Atti di convegno
Keywords:
electron cyclotron emission; plasma diagnostics; Martin-Puplett interferometer
List of contributors:
Garavaglia, SAUL FRANCESCO; Sozzi, Carlo; Simonetto, Alessandro
Book title: