Modelling of cardiovascular system: Development of a hybrid (numerical-physical) model

Academic Article
Publication Date:
2003
abstract:
Physical models of the circulation are used for research, training and for testing of implantable active and passive circulatory prosthetic and assistance devices. However, in comparison with numerical models, they are rigid and expensive. To overcome these limitations, we have developed a model of the circulation based on the merging of a lumped parameter physical model into a numerical one (producing therefore a hybrid). The physical model is limited to the barest essentials and, in this application, developed to test the principle, it is a windkessel representing the systemic arterial tree. The lumped parameters numerical model was developed in LabVIEW(TM) environment and represents pulmonary and systemic circulation (except the systemic arterial tree). Based on the equivalence between hydraulic and electrical circuits, this prototype was developed connecting the numerical model to an electrical circuit - the physical model. This specific solution is valid mainly educationally but permits the development of software and the verification of preliminary results without using cumbersome hydraulic circuits. The interfaces between numerical and electrical circuits are set up by a voltage controlled current generator and a voltage controlled voltage generator. The behavior of the model is analyzed based on the ventricular pressure-volume loops and on the time course of arterial and ventricular pressures and flow in different circulatory conditions. The model can represent hemodynamic relationships in different ventricular and circulatory conditions.
Iris type:
01.01 Articolo in rivista
Keywords:
Electro hydraulic gyrator; Hybrid model; Mock circulatory system; Physical model; Variable elastance model; Ventricular model
List of contributors:
DE LAZZARI, Claudio; Ferrari, Gianfranco
Handle:
https://iris.cnr.it/handle/20.500.14243/336517
Published in:
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS
Journal
  • Overview

Overview

URL

http://www.scopus.com/record/display.url?eid=2-s2.0-1242342171&origin=inward
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)