Deposition measurement of particulate matter in connection with corrosion studies

Academic Article
Publication Date:
2006
abstract:
A new passive particle collector (inert surrogate surface) that collects particles from all directions has been developed. It was used to measure particle deposition at 35 test sites as part of a project that examined corrosion of materials in order that variation in particulate material could be used in development of dose-response functions in a modern multipollutant environment. The project, MULTI-ASSESS, was funded by the EU to examine the effects of air pollution on cultural heritage. Passive samplers were mounted rain-protected, and both in wind-protected and wind-exposed positions, to match the exposure of the samples for corrosion studies. The particle mass and its chemical content (nitrate, ammonium, sulfate, calcium, sodium, chloride, magnesium and potassium) were analysed. The loss of light reflectance on the surrogate surface was also measured. Very little ammonium and potassium was found, and one or more anions are missing in the ion balance. There were many strong correlations between the analysed species. The mass of analysed water-soluble ions was fairly constant at 24% of the total mass. The particle mass deposited to the samplers in the wind-protected position was about 25% of the particles deposited to an openly exposed sampler. The Cl-/Na+ ratios indicate a reaction between HNO3 and NaCl. The deposited nitrate flux corresponds to the missing chloride. The Ca deposition equals the SO42-deposition and the anion deficiency.The SO42-deposition most likely originates from SO2 that has reacted with basic calcium-containing particles either before or after they were deposited. The particle depositions at the urban sites were much higher than in nearby rural sites. The deposited mass correlated surprisingly well with the PM10concentration, except at sites very close to traffic.
Iris type:
01.01 Articolo in rivista
Keywords:
Corrosione; Acido Nitrico; Particelle
List of contributors:
DE SANTIS, Franco
Handle:
https://iris.cnr.it/handle/20.500.14243/49440
Published in:
ANALYTICAL & BIOANALYTICAL CHEMISTRY (PRINT)
Journal
  • Overview

Overview

URL

http://www.springerlink.com/content/0t484t2076x4834g/fulltext.pdf
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)