The Role of the Characteristic Load Impedance in Passive Ladder Networks: Again the Presence of the Fibonacci Sequence
Articolo
Data di Pubblicazione:
2016
Abstract:
This paper deals with an analysis of the different
behaviors existing between ladder networks (LN) terminated
and not Phi terminated by the characteristic impedance Z0. The
main purpose of this work is to find, in both cases, links with the
golden ratio and, as a consequence, with Fibonacci numbers.
Results of some simulations related to the determination of
impedances, node voltages and branch currents are given in
order to underline approximation effects on the node voltages
and branch currents related to both the presence and absence of
Z0.This study has been firstly applied to R-R ladder networks
but it is here extended to consider other kinds of LNs, having
other types of single cells such as C-C ; L-L whose characteristic
impedances have also been determined.
Double resistive LN have also been investigated for which
impedances in any cell, currents in any branch and voltages in
any node have been determined in the two cases of presence
and absence of the characteristic impedance and with different
ratio between longitudinal and transversal impedances. This
study has another not less relevant aim: find one of the possible
platform for the modelization of biosystems like DNA and RNA,
because these structures even if much more complex look like a
LN
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Passive ladder Network; DNA; RNA; Fibonacci
Elenco autori:
LO CASTRO, Fabio
Link alla scheda completa:
Pubblicato in: